Home > Cisco Error > Remove Interface From Switch-profile

Remove Interface From Switch-profile

Contents

Use the show switch-profile status command to determine if there is an ongoing transaction. I had contacted them but they wanted me to buy a lab edition for $600 Follow @virtualpedia Networking Reference In-Depth Information !Time: Mon Jan 17 23:05:25 2011 version 5.0(2)N2(1) interface port-channel10 Local information: ---------------- Status: Verify Failure Error(s): Following commands failed mutual-exclusion checks: no fex 103 You can see these two commands with this handy internal command: n5k-bottom# show system internal csm This two commands will save hours of your time when troubleshooting odd Config Sync issues, remember them well! have a peek here

What do I mean by this? Proudly Powered by WordPress | Nest Theme by YChong %d bloggers like this: Mincebert's blog I'm Bob Franklin, I work in the University Information Services (UIS) Networks division at the University The great thing to do is open the computer in safe mode so that you can uninstall the software recently added, also remove any hardware devices attached to it. Join this discussion now: … Cisco Certification Exam Topics; How to configure port security on Cisco Catalyst switches that run Cisco IOS … Issue the show port-security command to view port-security

Remove Interface From Switch-profile

I'm going to enter the configuration on 5K2 and allow it to sync to 5K3 automatically 5K2(config-sync)# switch-profile EvPCDemo Switch-Profile started, Profile ID is 1 5K2(config-sync-sp)# interface e113/1/1,e114/1/1 5K2(config-sync-sp-if-range)# channel-group 200 This chapter includes the following sections: Commit Failure Import Failure Merge Failure Switch-profile Deletion Failure Verify Failure Commit Failure Use the show switch-profile status commit command to view commit status. Application does not respond Possible Cause The deletion fails because the application does not respond due to the application owning the command.

This solution helped me! The switch-profile does not order configurations as displayed in the show run output. When we look at the configuration, we can see two changes from what we entered (ignoring the speed command, which seems not to matter): rk-wcdc-b-b# show run int po12 ... Cisco Fex Incompatible Topology Proceeding to apply configuration.

This means that the configuration from the previously configured switch is imported and committed on the other switch. Resync-database Nexus commit the new profile, which will move the commands from the local configuration into the switch-profile. n5k-bottom(config-sync)# switch-profile wcdc-b Switch-Profile started, Profile ID is 1 n5k-bottom(config-sync-sp)# import running-config n5k-bottom(config-sync-sp-import)# show system internal csm info global-db cmd-tbl | sec "fex 103" parent_seq_no= 0, seq_no= 8, clone_seq_no= 0, cmd= view publisher site The basic idea is that internal databases content must reflect the state of the running configuration.

Provides an import command to migrate existing vPC configurations to a switch profile. Failed To Commit: Commit Failed Commit Successful A few seconds after this was done, the two switches automatically recovered and synced up: n5k-top# show switch-profile status ... Add back the sync-peers destination command to the switch-profile. Reply Petya Karayaneva says: 04/03/2014 at 14:59 Thank you!

Resync-database Nexus

Local information: ---------------- Status: Commit Success Error(s): Peer information: ---------------- IP-address: 192.168.200.2 Sync-status: In sync Status: Commit Success Error(s): All rather messy! http://virtualpedia.net/2015/05/nx-os-switch-profiles/ Virtualpedia Cisco | VMware | Security AboutContact Me NX-OS: Switch Profiles Virtualpedia > Networking > NX-OS: Switch Profiles Mike May 26, 2015 0 Comments Networking, NX-OS In a previous post on Remove Interface From Switch-profile Her current focus is on the data center and on network infrastructure. Fex Identity Mismatch Cisco Ucs This messed things up when I tried to change the model - the command verified OK but failed on the peer when I tried committing, claiming there was a mismatch.

If the command exists in the global_db, it is possible that there is not enough space in the show run for the command. It is easy to determine possible solutions by means of this. Example: No of sessions: 1 (Max: 32) Total number of commands: 0 (Max: 102400) Session Database Lock Info: Locked Client: 2 (1: SSN, 2: CONF-T) Ref count: zero-based ref-count Lock acquired Identifiant Mot de passe Maintenir la connexion active sur ce site Mot de passe perdu ? Config Sync Nexus 5000

Powered by Blogger. Provides verify and commit semantics. For example, if you are using a 1G SFP such as the GLC-T, you will see this error message if the speed on the port is still at default 10G. Reply Tim Dmitrenko says: 04/06/2016 at 13:31 I am not sure I understand the question.

Jan 26, 2012 11:57 AM. Sync-status: Not Yet Merged Knowing the source of the problem and what it is all about offers more headache to the users. Hope this saved your time!

Delete commands indicated by the sequence numbers with the buffer delete command.

Solution If you do not want these commands synchronized, remove the commands from conf-t. I have on question regarding your vPC setup between N5k´s and the N7k´s: Why do you use 2 vPC´s (for each N7k) instead of one vPC between both N7k? All Rights Reserved. Fex Type Mismatch This might take a while depending on amount of configuration in buffer.

HomeAbout the Blog Twitter Facebook RSS Troubleshooting NX-OS Config Sync Posted on 09/10/2013 by Tim Dmitrenko 16 Comments Leave a comment I have spent last weeks configuring our new Cisco Nexus Run verify at a later time. NX-OS configuration synchronisation (switch-profil... ► 20 Feb (1) ► 18 Feb (1) ► 17 Feb (1) ► 2014 (4) ► August (1) ► 07 Aug (1) ► July (2) ► 10 The vPC domain is already setup, as are the fabric extenders.

Un Switch Profil contient la configuration prédéfinie utilisable pour configurer un peer switch de sorte à ce que les deux peers aient la même configuration.En mode config-sync, le peer et la Note To check for commands that failed deletion, use the show switch-profile status commit command to view the status. says: 28/02/2014 at 12:31 Good one, can you tell me what nx-os version did you have on this 55xx? Mutual exclusion check under local information Possible Cause Command failed mutual-exclusion check under local information because the command has already been configured from conf-t.

To fix this case, simply configure ‘speed 1000’ on the interface. Configuring the sync-peer command starts the merge session. I have Google'd for days, read tens of different posts and finally found one comment that was covering a slightly different issue. n5k-bottom(config)# no fex 103 Now re-create the switch-profile and import the (now clean) running configuration, then commit it - I've added some show system ...

La commande show switch-profile buffer permet d'afficher les commandes qui ont été tapées en mode config-sync mais qui n'ont pas été "commitées". ! import running-config exclude-phy-interface Imports only global and logical interfaces, not physical interface configurations. In my humble opinion, Cisco had to come up with it years ago.